Gonyautoxin 6

CAS 82810-44-4 (free base)
Code CRM-00-GTX6
·
Lot 24-001
Gonyautoxin-6 · Formula: C10H17N7O8S · CAS: 82810-44-4 (free base)
Concentration
[GTX6] = (10.3 ± 0.9) µg/g
Purity
≥97%
Matrix / solvent
Liquid. Aqueous [AcOH] = 25 µM, pH = 4.95
Quantity
5 µg in
0.5 mL

Pricing and the Certificate of Analysis are available on request. Contact our team or download the CoA before purchase.

Specifications

Specifications

Every value below corresponds to the product lot and carries a stated measurement uncertainty where applicable. Fields marked to confirm must be completed from the verified product brief before publishing.

Product name
Gonyautoxin 6
Common name
Gonyautoxin-6
Short name
GTX6
CAS number
82810-44-4 (free base)
IUPAC name
to confirm
Molecular formula
C10H17N7O8S
Molecular weight
395.35 g·mol-1
Monoisotopic MW
395.10 g·mol-1
Product code
CRM-00-GTX6
Lot
24-001
Purity
≥97%
Concentration
[GTX6] = (10.3 ± 0.9) µg/g
Matrix / solvent
Liquid. Aqueous [AcOH] = 25 µM, pH = 4.95
Format
Amber glass vial (approx. 0.5 ml)
Fill volume / quantity
5 µg in
0.5 mL
Long-term storage
-20°C Material included in a Technical Annex of an ISO 17034 accreditation (Cifga Laboratory is a reference materials producer accredited by ENAC with accreditation Nº 2/PMR003).
Shelf life / stability
to confirm
Transport / hazard class
to confirm
Available from stock
Yes (to confirm)
Applications

Intended use & applications

This Azaspiracid-4 standard is used to calibrate, validate and run quality control on LC-MS/MS methods for the determination of azaspiracid-group toxins in shellfish. Analytical teams running official monitoring programmes rely on a standard with a known concentration and uncertainty to confirm instrument response and method performance batch after batch.

Developed through more than a decade of standards-production experience, the material supports control laboratories, contract testing labs and research centres working on marine-biotoxin determination. For method anchoring against a certified value, it pairs with CIFGA’s marine-toxin certified reference materials.

CIFGA · in-house standard preparation
Shellfish monitoring · azaspiracid-group control
Regulatory context

Regulatory context

Azaspiracids are lipophilic marine biotoxins regulated in the European Union under shellfish food-safety legislation, with official control based on LC-MS/MS following the EU Reference Laboratory method. [Confirm exact regulation references — e.g. Reg. (EC) 853/2004, 2074/2005 and the applicable AZA maximum level — before publishing.]

For laboratories operating under these requirements, a standard with a documented concentration and uncertainty is what makes a quantification result defensible in an audit. Using an ungraded standard instead introduces an uncontrolled source of error into the measurement chain.

Documentation

Documentation

Each batch ships with a downloadable Certificate of Analysis and Safety Data Sheet. The Certificate is available on request before purchase, so you can review the assigned value and uncertainty before committing to an order. The safety data sheet is available for direct download by registered users.

Certificate of Analysis
Why choose CIFGA

Why choose CIFGA

Unlike distributors who resell third-party material, CIFGA designs, produces, purifies and characterises this standard in-house — giving you full traceability from biological source to vial. As an ISO 17034-accredited producer of certified reference materials (ENAC Nº 02/PMR003), CIFGA applies the same metrological discipline across its catalogue, including its quality control standards.

As a European producer, deliveries reach EU laboratories without customs friction, with full cold-chain logistics and same-timezone technical support. Need a different concentration, format or analyte mixture? Our custom mixes and tailored services cover requirements outside the standard catalogue.

In-house production · biological source to vial
Related materials

Related reference materials

Other azaspiracid-group and marine-biotoxin standards frequently used alongside this material.

Application areas

Quality controlled standards and test kits for laboratories running chemical testing on textiles and garments according to REACH restrictions and recognised ISO methods.

Application areas

Bespoke mixtures, on-demand concentrations and contract purification, developed by CIFGA’s analytical production team.

Research workflows rarely fit a standard catalogue. A method under development may need a mixture of analytes at ratios that do not exist commercially. A validation study may require a concentration outside the available range. A novel compound may need isolation and characterisation before it can be used as a working standard.

These are the situations CIFGA’s tailored services are built for. Using CIFGA’s biotechnology production infrastructure and analytical expertise, we design and produce custom standards, bespoke mixtures and on-demand analytical solutions to meet the specific requirements of your laboratory.

Application areas

The batches obtained for standards defined as Quality Controlled Standards (QCSs) do not allow carrying out all the study requirements due to the limited size. However, they have been developed following the guidelines of ISO Guides Series 30, and the analytical method for quantification and assignment of purity is liquid chromatography coupled to ESI-MS/MS.

Application areas

Analytical standards and contract services for pharmaceutical quality control, produced at our facility in Lugo, Spain and supplied to laboratories in over 40 countries.

Application areas

Accurate mycotoxin analysis starts with the reference material behind it. CIFGA designs and produces Quality Control Standards and Certified Reference Materials for mycotoxin testing, certifying CRMs through a production process with full metrological traceability from source to Certificate of Analysis. A focused catalogue from a European primary producer.

Application areas

This section includes those materials standing for the matrixes where the analytes of interest are usually present. It has been designed to check the behavior of the matrix with your method of analysis.

Get started

Need Gonyautoxin 6 or a custom standard?

Add it to your quote request, or talk to our team about concentrations, formats and documentation.